Operations
Operate the local agent with metro failover, automatic updates, telemetry and troubleshooting
Regions and failover
The agent chooses a primary metro and keeps other reachable metros available for failover.
Automatic metro selection
Leave upstreams unset for automatic selection. The agent follows available metros and favors low round trip time. See Endpoints for hostnames.
Pinned metros
Set a pinned upstream list only when you need to restrict the available metros. Pinning also restricts failover: the agent will not use an unlisted metro when every listed metro is unavailable.
Metro changes
The agent checks reachable edges and changes its choice when a better connection is available or the current connection fails. Small latency differences may not cause a switch. Ordinary failover needs no restart.
If the agent chooses an unexpected metro, check the pinned list, DNS and outbound UDP access from the host. If the problem persists, ask on Discord.
Handle connection failover
If an edge connection closes during a request, the agent may send the same request through another edge. The first edge may already have forwarded it, so delivery can happen twice. Check the signature before sending a replacement.
When a request needs an edge and none is available, it can return not_ready with waiting_for: upstream. Check network access and the service log. See Confirmation for uncertain outcomes.
Share edge connections
An edge allows up to 32 QUIC connections per API key. Agents and direct QUIC clients using that key share the limit. Reuse running agents and client connections across sends.
Automatic updates
Release checks
The licensed agent updates automatically. Before installing a release, it verifies the release and checks that it can start with your configuration and reach an edge. The running release keeps serving during the check and stays in place if the check fails.
Keep the host ready
Keep the executable directory writable by the agent's account, including under service sandboxing. With systemd's ProtectSystem=strict, use ReadWritePaths=/opt/zerocopy as in the service example. When launching through a symbolic link, the target directory must be writable.
Keep the configuration readable and valid. Updates preserve owner access to the executable and remove group and other permissions.
Reconnect clients
Installation closes local HTTP, QUIC and IPC connections. Reconnect once the listeners return. IPC clients must open a new session and repeat the handshake. A lost reply leaves the outcome unknown; check the signature before replacing the transaction.
Run --check to see the installed release number.
Update failures
Diagnose an attempt
Read journalctl -u zerocopy-agent for warnings with release= and error= fields.
| Error | Action |
|---|---|
install or Permission denied | Check executable directory ownership, read only mounts and service sandboxing |
staged release failed its check | Include the preceding error: lines when contacting support |
| Network access failure | Restore outbound access to the metro hosts |
error: restart <path> on standard error | Check that the executable can run; the example service restarts after a process failure |
The running release remains in service when an update attempt fails. After fixing a host problem, restart the service to trigger a fresh attempt. Ask for help on Discord if the failure persists.
Replace the executable manually
When ZeroCopy provides a replacement, stop the service, follow installation, verify its checksum and start the service again.
Telemetry
Telemetry is required for the licensed agent and cannot be turned off. Your license agreement and the Privacy Notice cover it.
Network access
Reporting uses the edge connection and needs no separate firewall rule. Keep the required outbound access available.
Reported data
| Category | Information |
|---|---|
| Agent and host | Release and build ID, host name, hashed machine ID specific to the application, operating system, kernel, architecture, CPU and memory information, DMI system vendor and product name, uptime, metro configuration and local listen addresses |
| Requests | Counts, outcomes, response latency and forwarding results |
| Connections | Edge latency, metro changes and connection failures, local connection counts and client activity counters |
| Updates and logs | Release changes, failed updates, warning and error log lines with their fields |
The agent hashes the machine ID on the host; the raw ID does not leave it. When the machine ID is unavailable, the agent uses a fallback ID, which may be shared by multiple hosts. The host name is reported separately.
Logs also go to standard output. With the example service, read them using journalctl -u zerocopy-agent.
Excluded transaction data
Telemetry does not include transaction bytes, signatures, bundle contents or request bodies. It does not include the IPC socket path or the full contents of your configuration file.
Troubleshooting
Startup errors
Read journalctl -u zerocopy-agent or the terminal's error: lines. Run --check to separate configuration and edge connectivity failures from listener failures.
| Error | Action |
|---|---|
GLIBC_2.39' not found | Use a supported platform with glibc 2.39 or newer |
unknown argument or --config requires a path | Pass --config /etc/zerocopy/agent.toml, optionally followed by --check |
read config | Check the path and make the file readable by zerocopy |
parse config, unknown field or the customer binary does not accept the config option | Use supported options; keep upstreams above table headers |
upstreams entry ... is not host:port with a host under sol.zerocopy.sh | Use a metro hostname and port |
invalid log filter | Fix log.level or the overriding RUST_LOG environment variable |
Address already in use | Stop the other process or give each agent different listener ports |
bind <address>: Operation not permitted | Match the service port restrictions to listen.http and listen.quic |
TPU client: I/O error: Operation not permitted | Keep SocketBindAllow=ipv4:udp:0 for outgoing QUIC sockets |
bind IPC ... No such file or directory | Create the socket directory or use the example service |
bind IPC ... Permission denied | Make the socket directory writable by zerocopy |
another instance holds the IPC socket lock or another instance is listening on the IPC socket | Stop the other agent or choose another IPC path |
IPC path exists and is not a socket owned by this user | Inspect the path; remove it only if it belongs to a stopped instance, or choose a new path |
Keep IPC paths shorter than 108 bytes. For no valid executable license data, no valid release slot or this build has no API key compiled in, verify the checksum and contact support for the correct licensed file.
The connectivity check fails
For no region answered in time, check that metro hostnames resolve to IPv4 addresses, outbound UDP 443 reaches them, the system clock is correct and any pinned metros are available.
If the connection is refused despite correct network access, contact support to check the license and API key.
Sends fail
| Rejection | Action |
|---|---|
not_ready, waiting_for: upstream | Check /health, the service log and network access |
not_ready, waiting_for: tip_vaults | Fetch tip accounts again shortly |
not_ready, waiting_for: token_price or lookup_table | Retry shortly, or tip in SOL to a static tip account |
missing_tip | Meet the returned minimum with a live tip account, a token tip or an enabled declared tip. Agent releases that predate token tips refuse token and lookup-table tips locally |
payment_required | Resolve the outstanding payment through Billing or support |
forward_failed | Check the signature before retrying |
unsupported for tip_floor | Query the tip floor on a hosted endpoint |
unsupported for bundles | Bundles are turned off for the key; contact support to discuss access |
Use requests with replies to diagnose problems. A request without a reply cannot report its rejection. See Errors for other refusals and Confirmation before resubmitting.
Local clients cannot connect
| Symptom | Action |
|---|---|
| HTTP connection refused | Wait for startup and check the address against listen.http |
| QUIC handshake fails | Use ALPN zerocopy-swqos/1 and the local certificate settings |
IPC ENOENT or connect: No such file or directory | Check listen.ipc and that the agent is running |
IPC EACCES or connect: Permission denied | Give the application socket access and restart it after a group change |
IPC ECONNREFUSED or connect: Connection refused | Check that an agent is listening, rather than a socket left by a stopped instance |
IPC sessions end or replies are missing
After a stop or update, reconnect and repeat the handshake. If a session closes immediately after a submission, compare your client with the record and ring rules.
For missing completions, make sure each submission requests a reply, uses a distinct request ID and that your client keeps draining completions. See submission flags. Set a timeout for every request. For no completion within 5 seconds, check the signature and service log before retrying.
One CPU core stays busy
With ipc_busy_poll = true, one core stays busy while any IPC client is connected, even an idle one. Set it to false, disconnect idle clients or restrict the agent's CPUs. See busy polling.
Contact support
Give support your team name, the --check output and the settings relevant to the problem. Include the error: lines and their site= codes. Remove credentials from anything you share, including URLs in logs or configuration. Never send the licensed executable.